A column generation approach for evaluating delivery efficiencies of collimator technologies in IMRT treatment planning

Show simple item record

dc.contributor Graduate Program in Industrial Engineering.
dc.contributor.advisor Taşkın, Zeki Caner.
dc.contributor.author Gören, Merve.
dc.date.accessioned 2023-03-16T10:28:54Z
dc.date.available 2023-03-16T10:28:54Z
dc.date.issued 2014.
dc.identifier.other IE 2014 G77
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/13337
dc.description.abstract Intensity Modulated Radiation Therapy (IMRT) is a form of cancer treatment which delivers radiation beams to the patient from several directions by using a linear accelerator and a collimator. At the leaf sequencing optimization step of the IMRT treatment planning, the intensity matrices are decomposed into a set of deliverable apertures and their associated intensities. Collimator systems used in IMRT can form di erent geometric shapes of apertures depending on their physical capabilities. Hence, comparing the delivery e ciency of di erent collimator technologies is important to determine the value added by the di erent technologies. In this thesis, we compare the e ciency of using regular, rotating and dual multileaf collimator (MLC) systems under di erent combinations of consecutiveness, interdigitation and rectangular constraints and a virtual freeform collimator. We formulate the problem of minimizing total beam-on time (BOT) as a large-scale linear programming problem. To deal with its dimensionality, we propose a column generation approach. Although there exists a general master problem structure, subproblem depends on the used collimator system technology. Therefore, we model each subproblem individually and apply a di erent solution method to each of them. We test our approach on a set of clinical problem instances. Our results indicate that the dual MLC under consecutiveness constraint yields very similar beam-on time as a virtual freeform collimator which can form any possible segment shape by opening or closing each bixel independently. Our approach provides a ranking between other collimator technologies in terms of their delivery e ciencies.
dc.format.extent 30 cm.
dc.publisher Thesis (M.S.)-Bogazici University. Institute for Graduate Studies in Science and Engineering, 2014.
dc.subject.lcsh Radiotherapy.
dc.title A column generation approach for evaluating delivery efficiencies of collimator technologies in IMRT treatment planning
dc.format.pages xiv, 60 leaves ;