Archives and Documentation Center
Digital Archives

Assessing a virtual reality display system for teleradiology purposes using the receiver operating curve methodology

Show simple item record

dc.contributor Graduate Program in Physics.
dc.contributor.advisor Kurnaz, M. Levent.
dc.contributor.advisor Güveniş, Albert.
dc.contributor.author Kocatürk, Eylem.
dc.date.accessioned 2023-03-16T10:37:19Z
dc.date.available 2023-03-16T10:37:19Z
dc.date.issued 2018.
dc.identifier.other PHYS 2018 K73
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/13626
dc.description.abstract In a radiology reading room, multiple flat displays are used for the comparison aspect. This approach increases the overall expense and also requires more space. So, virtual reality techniques can be applied to teleradiology. By using VR devices, radiologists may complete diagnostic tasks outside of hospital settings. In this study, 100 lung X-ray images with definite findings were gotten from the database approved by the radiologists. Five radiologists from Yeditepe University Hospital assessed these images both on a medical grade LCD monitor and on the Oculus Rift CV1. The receiver-operating characteristic (ROC) curves for all display reader cases were statistically compared to check observers’ performances. AUC for virtual reality head mounted display for reader 1, 2, 3, 4,5 and overall were calculated as 0.931, 0.865, 0.805, 0.775, 0.728 and 0.814 respectively. AUC for medical monitor were 0.948, 0.915, 0.897, 0.771, 0.769 and 0.861. Sensitivity and specificity of p values from McNemar test were 0,37 and 0.90 respectively. Since, the p values are greater than 0.05, this is a good indicator of no difference between two diagnostic techniques. Weighted kappa results for reader 1, 2, 3, 4, 5 and overall were 0.656, 0.782, 0.557, 0.383, 0.224 and 0.542 respectively. So, the overall weighted kappa value showed the moderate agreement between two diagnostic techniques.So, Oculus Rift CV1 can be used as a diagnostic display by the radiologists.
dc.format.extent 30 cm.
dc.publisher Thesis (M.S.) - Bogazici University. Institute for Graduate Studies in Science and Engineering, 2018.
dc.subject.lcsh Radiology, Medical.
dc.subject.lcsh Radiography.
dc.subject.lcsh Telecommunication in medicine
dc.title Assessing a virtual reality display system for teleradiology purposes using the receiver operating curve methodology
dc.format.pages xiv, 69 leaves ;


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Archive


Browse

My Account