Archives and Documentation Center
Digital Archives

A study on the stability of the led gain monitoring system for the CMS-HF PMTs during 2009

Show simple item record

dc.contributor Graduate Program in Physics.
dc.contributor.advisor Gülmez, Erhan.
dc.contributor.author Özbek, Melih.
dc.date.accessioned 2023-03-16T10:38:08Z
dc.date.available 2023-03-16T10:38:08Z
dc.date.issued 2010.
dc.identifier.other PHYS 2010 O83
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/13709
dc.description.abstract The Hadronic Forward (HF) calorimeter improves the jet detection and the missing transverse energy resolution of the Compact Muon Solenoid (CMS). In HF, the Photo Multiplier Tubes (PMTs) convert optical signals (i.e., Čerenkov light) to electrical signals. For monitoring the PMT gains, LED signals are extensively used. LED data collected throughout 2009 were thoroughly studied in this thesis. The focus was analyzing the stability of the LED system over time by graphical means. Also, by plotting the average charge versus position, it was possible to identify problematic channels.
dc.format.extent 30cm.
dc.publisher Thesis (M.S.)-Bogazici University. Institute for Graduate Studies in Science and Engineering, 2010.
dc.subject.lcsh Particles (Nuclear physics)
dc.subject.lcsh Particle acceleration.
dc.title A study on the stability of the led gain monitoring system for the CMS-HF PMTs during 2009
dc.format.pages xiii, 46 leaves;


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Archive


Browse

My Account