dc.description.abstract ETA-B Building located in Bo gazi ci University, North Campus is monitored before, during and after its retro tting process by previous researchers. An Enhanced Frequency Domain Decomposition identi cation algorithm is developed in this study to be able to analyse the gathered data. The results of these analysis is then used along with the Finite Element Models generated in this study to perform model updating procedures. The updated and non-updated Finite Element Models are then subjected to linear time history analysis for a selection of earthquakes and the storey drift ratios are compared to evaluate the e ect of Structural Health Monitoring on the obtained results. The results indicate that Structural Health Monitoring could have a distinct impact on the decision making process for safety approval, retro tting or demolishing decisions for existing structures. The theory and background for Structural Health Monitoring is also made available in this thesis, along with discussions on what it could and could not currently enable in terms of its possible uses, advantages and shortcomings.
dc.format.extent 30 cm.
dc.publisher Thesis (M.S.) - Bogazici University. Institute for Graduate Studies in Science and Engineering, 2013.
dc.subject.lcsh Structural dynamics -- Mathematical models.
dc.subject.lcsh Finite element method.
dc.title Modal testing of a retrofitted building
dc.format.pages xiv, 100 leaves ;