Arşiv ve Dokümantasyon Merkezi
Dijital Arşivi

Experimental study on mitigation of earthquake hazards using geosynthetics

Basit öğe kaydını göster

dc.contributor Graduate Program in Civil Engineering.
dc.contributor.advisor Edinçliler, Ayşe.
dc.contributor.advisor Baykal, Gökhan.
dc.contributor.author Sekman, Mustafa.
dc.date.accessioned 2023-03-16T10:50:59Z
dc.date.available 2023-03-16T10:50:59Z
dc.date.issued 2016.
dc.identifier.other CE 2016 S46
dc.identifier.uri http://digitalarchive.boun.edu.tr/handle/123456789/13984
dc.description.abstract In this study, it is aimed to experimentally evaluate the e ectiveness and robustness of an applicable, low-cost alternative seismic isolation (SI) system valid for low-rise and mid-rise buildings. This alternative SI system is comprised of a geotextile laid over a geomembrane located within a soil pro le beneath the structure with a cylindrical shape. Because of involving geotechnics in contrast to conventional SI, proposed alternative SI system is named as Geotechnical Seismic Isolation (GSI). To obtain results that are more reliable, and to observe soil structure behavior during the excitation, an experimental setup was developed. For this purpose, a laminar box and 1:10 scaled building models were constructed. The e ectiveness of the proposed GSI system was assessed by comparing the response of performed shaking table experiments with and without utilizing proposed alternative SI system. E ects of the number of the story of the building, horizontal length to depth ratio of geosynthetics, type of geosynthetics and ground motion characteristic on GSI system were investigated. Due to the curved shaped nature of the geosynthetic layer, permanent slips are diminished by the restoring e ect of the gravitational forces of the isolated soil and structure mass. The comparative results of experiments revealed that GSI system can reduce the horizontal accelerations, horizontal drifts, Arias intensity, base shear, and base moment of the building. By using the proposed GSI isolation system, seismic energy transmitted from ground to structure is dissipated through slip displacement between geotextile and geomembrane.Noticeable reductions due to proposed GSI system can improve the resistance capacity of the structures against strong ground motions.
dc.format.extent 30 cm.
dc.publisher Thesis (M.S.) - Bogazici University. Institute for Graduate Studies in Science and Engineering, 2016.
dc.subject.lcsh Geosynthetics.
dc.subject.lcsh Buildings -- Earthquake effects.
dc.title Experimental study on mitigation of earthquake hazards using geosynthetics
dc.format.pages xxii, 156 leaves ;